Steam Tracing - Manifold to Manifold

Page 1

TRACE DIVISION TURN - KEY | TESTED www.sli services.com | Tel: 713-943-3443 Steam Tracing Systems & Manifolds

STEAM TRACING SOLUTIONS

SLIS provides Manifold-TO-Manifold installations and designs. The SLIS steam tracing system includes full packages of steel Forge Manifolds.

The type MSC forged steel manifolds centralize steam distribution and condensate collection for up to 12 sources. Steam Manifolds have variety of connections, making them particularly well suited for tracing applications. The compact design provides easy access for trap maintenance and monitoring, while the mounting arrangement permits quick installation. The condensate collection manifold includes an internal siphon pipe to promote even temperature distribution and ensure single-phase discharge of condensate. The quality systems of SLIS offer a trustworthy and easily operational system that is plant friendly and meets the demands of everyday processes.

Engineered Steam Tracing Solutions: Manifold-TO-Manifold

The general practice of heating piping as material flows through it to keep the materials at a constant temperature and compensate for heat loss is known as heat tracing. In the case of steam tracing the heat is generated excess steam from other processes.

Steam Tracing Solutions

STEAM TRACING SYSTEMS EXTEND BEYOND THE PIPING,
AND EQUIPMENT
VESSELS,

STEAM DISTRIBUTION MANIFOLDS

MSC Manifolds for Steam Distribution

These manifolds have been designed for vertical installation. The back is provided with M12 threaded connections for ease of installation by attaching t supporting structure.

For ease of installation it isrecommended that spacers are fitted to give the manifold a standat least 2" (50mm). Following installation, it is recommended that the manifold is insulated to minimize radiated heat losses and to protect personnel from burn risks.

For convenience the following mounting kits (comprising 50mm spacers and M12 studs and nuts) and thermal insulation blankets are available.

DistributionManifoldsavailable in4,8&12

ASSORTED TRAPS

Available

Thermodynamic Steam Trap

Trap Valve Station

Up to 899 psig

Inverted Bucket Steam Trap

Float & Thermostatic Steam Trap

More Engineered Steam Tracing Solutions

Manifold-TO-Manifold Design & Installation

CollectionManifolds availablein4,8 &12

Condensate collection duty

The recommended installation is with the condensate outlet at the top. The bottom of the manifold should be fitted with a stop valve for blowdown purposes. Again, we recommend that a diffuser is fitted.

All units are hydro tested to 1.5 times design pressure, and painted with industrial heat resistant coating (Black) with a maximum temperature of 850ºF

Engineered Steam Tracing Solutions

TYPES OF STEAM APPLICATIONS

• Conventional Tracing

• Single & Double Insulated Tube

• Bare Tube with HTC

• Snap Trace

• Contro Trace

• Hot Oil

DESCRIPTION

The type MSC forged steel manifolds centralize steam distribution and condensate collection for up to 12 sources.

Both models have integral piston valves with a variety of connections, making them particularly well suited for tracing applications.

The compact design provides easy access for trap maintenance and monitoring, while the mounting arrangement permits quick installation.

The condensate collection manifold includes an internal siphon pipe to promote even temperature distribution and ensure single-phase discharge of condensate.

COLORED Pre-Insulated Tubing Available

Colored Jacketing available

▪ Steam = Red

▪ Condensate = Blue

▪ Standard = Black

For better identification of the supply and return preinsulated tubing, we offer color coded Tubing bundles

HEAT TRACING SOLUTIONS FOR PIPING, TANKS, AND INSTRUMENTATION

WE ALSO PROVIDE THE FOLLOWING SERVICES

▪ HEAT TRACING SYSTEMS ‒ STEAM & ELECTRIC

▪INDUSTRIAL INSULATION

▪SCAFFOLDING SERVICES

▪STRAIGHT- WRAP REMOVABLE AND REUSABLE BLANKETS

▪STANDING SEAM TANK PANELS

▪MAINTENANCE SERVICES

▪CUI & INSULATION SURVEYS

▪SLIS OFFERS SURVEYS FOR: STEAM TRAPS, AIR & NITROGEN

TURN-KEY DESIGN/SUPPLY INSTALLATION Maintenance

Electric Heat Tracing Systems

•Complete Heat Tracing Design

•Install Heat Tracing Cables and Accessories

•Make All Terminations

•Mount Transformers and Control Panels

•Run Conduit and Wire

•Install Thermal Insulation

•Test and Commission Complete System

• Texas Electrical License

Instrument Tubing Systems

•Complete Heat Tracing Design

•Mount Instruments and Support Structures

•Install Heated Enclosures

•Install Instrument Tubing

• Make All Connections and Terminations

•Test and Commission Complete System

Steam tracing is a process that is designed to prevent Heat Loss as materials are moved through a piping process system. A common application for this process is in the oil/gas industry. The piping at refineries is commonly fitted with steam tracing equipment. Using this technique allows refineries, chemical plants and storage terminals to safely and efficiently control the heating of their processes.

Steam/Fluid Systems

• Manifold-TO-Manifold design and installation

•Complete Heat Tracing Design

•Layout Tracer Tubing

•Install Heat Transfer Compound

•Run Steam Supply/Condensate Return Tubing

•Make All Tubing Connections

•Install Thermal Insulation

•Test and Commission Complete System

SLIS is available for expert advice on making decisions in regards to industrial insulation. Whether if it is pipe spools, vessels, instrumentation or other process equipment, SLIS will be able to provide Turnkey project for any type of application.

SLIS is a true systems approach company, which means that a project manager will help in the problem-solving process from inception and design of project, through completion. SLIS is accomplished in both EHT and Steam tracing systems, and has access to a wide array of electrical controls and monitoring equipment. This is all to ensure that the heat trace system is tailored to your requirements.

PIPING, TANKS, AND INSTRUMENTATION

HYDROTEST SYSTEM CHECKLIST

HYDROSTATIC TEST Report for your system will be included:

✓ Any Bank Steam Size Manifold Distribution

✓ Leak Detection

✓ Tested at 285 PSI

✓ 15 Minute Duration Test

✓ Fully Tested

✓ Signed and Approved

✓ optimization

Leak Detection Test

Ensures that there are no leaks on any steam bank distribution manifolds

Fully Tested Before Install

Run 15 Minute Duration for any leak detection.

Other Assessments

✓ PT Testing & X-Ray Testing Optional

✓ Thermal Insulation inspection

✓ Heat Trace system installation inspection

✓ Heated enclosure inspection

✓ Temperature controller/thermostat test

✓ Electrical wire connection inspection

Additional Testing Upon Request

PT Testing & X-Ray Testing

✓ Conduit distribution system and fittings

HEAT TRACING DIVISION 1101 Michigan St.- South Houston, TX 77587 Tel: +1-713-943-3443 | Tel: +1-877-479-5071 www.sli-services.com | sales@sli-services.com